==== General purpose ====
  • Prepare your Fluent job using Fluent from the "ANSYS Workbench" on your Desktop machine up to the point where you would run the calculation.
  • Export the "case" file "File > Export > Case..." or find the folder where Fluent saves your project's files. The "case" file will often have a name like FFF-1.cas.gz.
  • If you already have data from a previous calculation, which you want to continue, export a "data" file as well (File > Export > Data...) or find it the same project folder (FFF-1.dat.gz).
  • Transfer the "case" file (and if needed the "data" file) to a directory on the project or scratch filesystem on the cluster. When exporting, you save the file(s) under a more instructive name than FFF-1.* or rename them when uploading them.
  • Now you need to create a "journal" file. It's purpose is to load the case- (and optionally the data-) file, run the solver and finally write the results. See examples below and remember to adjust the filenames and desired number of iterations.
  • Adapt the Fluent jobscript below to your needs.
  • After running the job you can download the "data" file and import it back to Fluent with File > import > Data....