ADF: Difference between revisions

From Alliance Doc
Jump to navigation Jump to search
No edit summary
m (add to Category:ComputationalChemistry)
 
(61 intermediate revisions by 5 users not shown)
Line 2: Line 2:


<translate>
<translate>
[[Category:Software]]
[[Category:Software]][[Category:ComputationalChemistry]]
==Introduction== <!--T:1-->
==Introduction== <!--T:2-->
The [https://www.scm.com/ ADF (Amsterdam Density Functional) Modeling Suite] offers powerful computational chemistry tools for many research areas such as homogeneous and heterogeneous catalysis, inorganic chemistry, heavy element chemistry, various types of spectroscopy, and biochemistry.
'''Important:''' ADF has been renamed to AMS since the 2020 version. Significant changes such as the input and output formats have been made in the new AMS. Please refer to [[AMS]] for more information.


<!--T:2-->
<!--T:46-->
The [https://www.scm.com/ SCM (Software for Chemistry and Materials) Amsterdam Modeling Suite] originally the ADF (Amsterdam Density Functional) Modeling Suite, offers powerful computational chemistry tools for many research areas such as homogeneous and heterogeneous catalysis, inorganic chemistry, heavy element chemistry, various types of spectroscopy, and biochemistry.
 
<!--T:4-->
Compute Canada users have access to the following products:
Compute Canada users have access to the following products:
*ADF
*ADF
Line 18: Line 21:
*NBO6
*NBO6


==Running ADF on Graham== <!--T:3-->
==Running SCM on Graham== <!--T:6-->
ADF and BAND are installed only on [[Graham]] due to license restrictions; versions 2016.106 and 2017.207 are currently available. To [[Utiliser des modules/en|load a module]], use the <code>module load</code> command specifying the version you select, for example
The <code>adf</code> module is installed only on [[Graham]] due to license restrictions. To check what versions are available use the <code>module spider</code> command as follows:
 
<!--T:8-->
[name@server $] module spider adf


<!--T:4-->
<!--T:10-->
[name@server $] module load adf/2017.207
For module commands, please see [[Utiliser des modules/en|Using modules]].


===Job Submission=== <!--T:5-->
===Job submission=== <!--T:12-->


<!--T:6-->
<!--T:14-->
Graham uses the Slurm scheduler; for details about submitting jobs, see [[Running jobs]].
Graham uses the Slurm scheduler; for details about submitting jobs, see [[Running jobs]].


====Single ADF or BAND run==== <!--T:7-->
====Single ADF or BAND run==== <!--T:16-->
This mysub.sh script is for a whole-node job. The last two lines load version 2017.207 and call ADF directly.
This mysub.sh script is for a whole-node job. The last two lines load version 2019.305 and call ADF directly.
</translate>
</translate>
{{File
{{File
Line 42: Line 48:
#SBATCH --output=adf_test-%j.log        # output file
#SBATCH --output=adf_test-%j.log        # output file


module load adf/2017.207
module unload openmpi
module load adf/2019.305
ADF adf_test.inp   
ADF adf_test.inp   
}}
}}
<translate>


<translate>
<!--T:18-->
<!--T:8-->
This is the input file used in the script:
This is the input file used in the script:
</translate>
</translate>
Line 74: Line 81:
  End Input
  End Input
}}
}}
<translate>
<translate>


====Multiple ADF or BAND runs within one input file==== <!--T:9-->
====Multiple ADF or BAND runs==== <!--T:20-->


<!--T:10-->
<!--T:22-->
Multiple calculations can be combined into a single job by creating a script such as this:
Multiple calculations can be combined into a single job by creating a input file such as this:
</translate>
</translate>
{{File
{{File
Line 219: Line 225:
mv TAPE21 H2O.t21
mv TAPE21 H2O.t21
}}
}}
<translate>


<translate>
<!--T:24-->
<!--T:11-->
The following slurm script is identical to the one used for a single run (mysub.sh), except the last line calls the GO_H2O.run script, instead of ADF.
The following script is identical to the one used for a single run (mysub.sh), except that  the last line calls the GO_H2O.run script, instead of ADF.
</translate>
</translate>
{{File
{{File
Line 234: Line 240:
#SBATCH --output=GO_H2O_%j.log          # output file
#SBATCH --output=GO_H2O_%j.log          # output file


module load adf/2017.207
module unload openmpi
./GO_H2O.run                           # run the shell script
module load adf/2019.305
bash GO_H2O.run                         # run the shell script
}}
}}
<translate>
<translate>


===Examples=== <!--T:12-->
===Examples=== <!--T:26-->
Example input/output for ADF can be found on Graham under
Example input/output for ADF can be found on Graham under
  /home/jemmyhu/tests/test_ADF/2017.207/test_adf/
  /home/jemmyhu/tests/test_ADF/2019.305/test_adf/


<!--T:13-->
<!--T:28-->
The same procedure applies to BAND jobs, see band_test.inp and band_test.sh examples under
The same procedure applies to BAND jobs, see band_test.inp and band_test.sh examples under
  /home/jemmyhu/tests/test_ADF/2017.207/test_band
  /home/jemmyhu/tests/test_ADF/2019.305/test_band/
</translate>
 
==Running SCM-GUI== <!--T:30-->
Rendering over an SSH connection with X11 forwarding is very slow for GUI applications such as ADF-GUI. We recommend you use [[VNC]] to connect if you will be running ADF-GUI.
 
===Graham=== <!--T:32-->
 
<!--T:34-->
ADF can be run interactively in graphical mode on a Graham compute node (3hr time limit) over TigerVNC with these steps:
 
<!--T:35-->
# [[VNC#Setup|Install a TigerVNC]] client on your desktop
# [[VNC#Compute_Nodes|Connect]] to a compute node with vncviewer
# <code>module load adf</code>
# <code>adfinput</code>
 
===Gra-vdi=== <!--T:36-->
 
<!--T:38-->
Adf can be run interactively in graphical mode on gra-vdi (no connection time limit) over TigerVNC with these steps:
 
<!--T:40-->
# [[VNC#Setup|Install a TigerVNC]] client on your desktop
# [[VNC#VDI_Nodes|Connect]] to gra-vdi.computecanada.ca with vncviewer
# <code>module load clumod</code>
# <code>module load adf</code>
# <code>adfinput</code>
 
<!--T:42-->
A tutorial pdf showing how to install, connect and run ADF-GUI using TigerVNC on gra-vdi can be found
[https://www.sharcnet.ca/~jemmyhu/TigerVNC-for-ADF-GUI.pdf here].


<translate>
===Locally=== <!--T:44-->
==Running ADF-GUI on Graham== <!--T:14-->
SCM has a separate license to run ADF-GUI on a local desktop machine. If you are interested contact [mailto:license@scm.com license@scm.com] to purchase your own license.  
ssh x11 rendering is very slow for remote GUI application such as ADF-GUI. User should use VNC to connect to graham and run ADF-GUI on Graham.


<!--T:15-->
Example for how to install, connect and run ADF-GUI using TigerVNC has been given in
[https://www.sharcnet.ca/~jemmyhu/TigerVNC-for-ADF-GUI.pdf TigerVNC-for-ADF-GUI]
It is also available on Graham under
/home/jemmyhu/tests/test_ADF/TigerVNC/
</translate>
</translate>

Latest revision as of 13:24, 19 July 2022

Other languages:

Introduction

Important: ADF has been renamed to AMS since the 2020 version. Significant changes such as the input and output formats have been made in the new AMS. Please refer to AMS for more information.

The SCM (Software for Chemistry and Materials) Amsterdam Modeling Suite originally the ADF (Amsterdam Density Functional) Modeling Suite, offers powerful computational chemistry tools for many research areas such as homogeneous and heterogeneous catalysis, inorganic chemistry, heavy element chemistry, various types of spectroscopy, and biochemistry.

Compute Canada users have access to the following products:

  • ADF
  • ADF-GUI
  • BAND
  • BAND-GUI
  • DFTB
  • ReaxFF
  • COSMO-RS
  • QE-GUI
  • NBO6

Running SCM on Graham

The adf module is installed only on Graham due to license restrictions. To check what versions are available use the module spider command as follows:

[name@server $] module spider adf

For module commands, please see Using modules.

Job submission

Graham uses the Slurm scheduler; for details about submitting jobs, see Running jobs.

Single ADF or BAND run

This mysub.sh script is for a whole-node job. The last two lines load version 2019.305 and call ADF directly.

File : mysub.sh

#!/bin/bash
#SBATCH --nodes=1 --ntasks-per-node=32  # 1 node with 32 cpus, you can modify it
#SBATCH --mem=0                         # request all memory on node
#SBATCH --time=00-03:00                 # time (DD-HH:MM)
#SBATCH --output=adf_test-%j.log        # output file

module unload openmpi
module load adf/2019.305
ADF adf_test.inp


This is the input file used in the script:

File : adf_test.inp

Title WATER Geometry Optimization with Delocalized Coordinates

 Atoms
    O             0.000000     0.000000     0.000000
    H             0.000000    -0.689440    -0.578509
    H             0.000000     0.689440    -0.578509
 End

 Basis
 Type TZP
 Core Small
 End

 Geometry
  Optim Deloc
  Converge 0.0000001
 End

 End Input


Multiple ADF or BAND runs

Multiple calculations can be combined into a single job by creating a input file such as this:

File : GO_H2O.run

#!/bin/bash
if test -z "$SCM_TESTOUTPUT" ; then SCM_TESTOUTPUT=GO_H2O.out; fi

$ADFBIN/adf << eor > $SCM_TESTOUTPUT
Title WATER Geometry Optimization with Delocalized Coordinates

Atoms
   O             0.000000     0.000000     0.000000
   H             0.000000    -0.689440    -0.578509
   H             0.000000     0.689440    -0.578509
End

Basis
Type TZP
Core Small
End

Geometry
 Optim Deloc
 Converge 0.0000001
End

End Input
eor

rm TAPE21 logfile
$ADFBIN/adf << eor >> $SCM_TESTOUTPUT
Title WATER Geometry Optimization in Cartesians with new optimizer

Atoms
    O             0.000000     0.000000     0.000000
    H             0.000000    -0.689440    -0.578509
    H             0.000000     0.689440    -0.578509
End

Basis
 Type TZP
 Core Small
End

Geometry
  Optim Cartesian
  Branch New
  Converge 0.0000001
End

End Input
eor

rm TAPE21 logfile
$ADFBIN/adf << eor >> $SCM_TESTOUTPUT
Title WATER Geometry Optimization with Internal Coordinates

Atoms    Z-Matrix
 1. O   0 0 0
 2. H   1 0 0   rOH
 3. H   1 2 0   rOH  theta
End

Basis
 Type TZP
 Core Small
End

GeoVar
 rOH=0.9
 theta=100
End
Geometry
  Converge 0.0000001
End

End Input
eor

rm TAPE21 logfile
$ADFBIN/adf << eor >> $SCM_TESTOUTPUT
Title WATER   optimization with (partial) specification of Hessian

Atoms    Z-Matrix
 1. O   0 0 0
 2. H   1 0 0   rOH
 3. H   1 2 0   rOH  theta
End

GeoVar
 rOH=0.9
 theta=100
End
HessDiag  rad=1.0  ang=0.1

Fragments
 H   t21.H
 O   t21.O
End

Geometry
  Converge 0.0000001
End

End Input
eor

rm TAPE21 logfile
$ADFBIN/adf << eor >> $SCM_TESTOUTPUT
Title WATER Geometry Optimization in Cartesians

Geometry
  Optim Cartesian
  Converge 0.0000001
End

Define
 rOH=0.9
 theta=100
End

Atoms    Z-Matrix
 1. O   0 0 0
 2. H   1 0 0   rOH
 3. H   1 2 0   rOH theta
End

Fragments
 H   t21.H
 O   t21.O
End

End Input
eor

mv TAPE21 H2O.t21


The following slurm script is identical to the one used for a single run (mysub.sh), except the last line calls the GO_H2O.run script, instead of ADF.

File : GO_H2O.sh

#!/bin/bash
#SBATCH --nodes=1 --ntasks-per-node=32  # 1 node with 32 cpus, you can modify it
#SBATCH --mem=0                         # request all memory on node
#SBATCH --time=00-03:00                 # time (DD-HH:MM)
#SBATCH --output=GO_H2O_%j.log          # output file

module unload openmpi
module load adf/2019.305
bash GO_H2O.run                         # run the shell script


Examples

Example input/output for ADF can be found on Graham under

/home/jemmyhu/tests/test_ADF/2019.305/test_adf/

The same procedure applies to BAND jobs, see band_test.inp and band_test.sh examples under

/home/jemmyhu/tests/test_ADF/2019.305/test_band/

Running SCM-GUI

Rendering over an SSH connection with X11 forwarding is very slow for GUI applications such as ADF-GUI. We recommend you use VNC to connect if you will be running ADF-GUI.

Graham

ADF can be run interactively in graphical mode on a Graham compute node (3hr time limit) over TigerVNC with these steps:

  1. Install a TigerVNC client on your desktop
  2. Connect to a compute node with vncviewer
  3. module load adf
  4. adfinput

Gra-vdi

Adf can be run interactively in graphical mode on gra-vdi (no connection time limit) over TigerVNC with these steps:

  1. Install a TigerVNC client on your desktop
  2. Connect to gra-vdi.computecanada.ca with vncviewer
  3. module load clumod
  4. module load adf
  5. adfinput

A tutorial pdf showing how to install, connect and run ADF-GUI using TigerVNC on gra-vdi can be found here.

Locally

SCM has a separate license to run ADF-GUI on a local desktop machine. If you are interested contact license@scm.com to purchase your own license.